If you are looking for an easy step by step instructional on how to plumb a drain then this is it.
Utility sink drain pipe height.
The last size is 4 inch drain pipe that can be connected to 160 units in horizontal stack and 240 units in vertical stack.
If the sink has a pop up drain the tailpipe will need to be long enough to house the drain mechanism.
It ll go towards the ceiling and if you follow it to the roof.
Toilet water exactly as speced by the mfr.
Cut section from existing drain pipe and install a new wye fitting 3.
One hole is 4 inches to the right of centerline.
Sink rough in details.
4 10 15 12 10 52 pm.
I will eventually have the sink tapped in to the.
Consider drain pipe to be the vertical centerline.
Lav drain exatly as speced by the mfr.
About 16 to 20 inches above the floor.
Tighten the compression nut on the tailpiece to.
Rough in the pvc trap assembly 6.
Set the utility sink in place against the wall where the rough plumbing drain is installed.
The fourth size is 3 inch drain pipe that can be connected to 20 units in horizontal stack and 30 units in vertical stack.
If the drain mechanism is not a concern and the vent pipe is not yet installed measure the.
I guess i will do 16 inches and is the 16 inches from the floor to the bottom of the pipe or floor to the center of the pipe.
Set the sink into position inserting its chrome tailpiece into the pvc trap 7.
This is the minimum size to use for building sewer or drain pipe that is connected to the toilet.
Plumbers must connect drains to the main sewer line and typically leave a pvc or metal pipe extending.
Pick a spot on the pipe above the wye fitting and near the ceiling.
Look for a length of pvc pipe splitting from the drain pipe.
Plumbing and piping laundry sink drain height.
The drain line connects to the sink via a p trap a curved piece that prevents sewer gas from entering the bathroom and a tailpiece a straight piece that extends from the sink drain to the trap in most cases a standard tailpiece is the right length to reach from the sink to the trap but in the case of a high drain line or an unusually low sink the tailpiece can be cut to fit.
Other is 4 inches to left of centerline discharge hole vertical.
Vertically both are about 2 to 3 inches above the drain pipe supply lines horizontal.
Laundry tub drain washer box wherever the designer or architect specs it icemaker box no box 1 4 line stubbed out above finished floor height.
Assemble pvc pipe and fittings for new drain vent system 4.
Use the hacksaw to sever the vent pipe.
Ks water 15 unless it is a wall mounted faucet ks drain 12 max laundry tub water in the guy grey box.
The vent pipe helps the sink drain and prevents sewer gas from entering the house.